Within an expanding office, there may be video conferencing, cloud applications, wireless access points, IP telephony and security. Therefore, reliable cabling is essential. The type of cables installed within a network can impact performance, reliability and scalability.
To determine which cables to use (Cat 6, Cat 6A or Fibre) consideration must be given to distance, desired bandwidth and the environment. Understanding the strengths of these different types of cables will assist in choosing the best network cabling layout for your business.
What is Structured Cabling?
Structured cabling consists of a range of cabling, sockets, patch panels and cabinets to allow devices to communicate. Planning the structured cabling layout well ensures easy management, and can allow for future additions and problems to be easily resolved.
Bluechip Kenya provide structured cabling, including Cat 6 and Fibre Optic cabling. They also provide rack cabinets, data & voice cabling, managed switches, wireless access points and IT set up within an office. Therefore, when designing cabling, consideration must be given to the network devices and the requirements of your business.
Cat 6 Cabling
- Cat 6 cabling- is often used to connect devices like computers, printers and IP telephones. Cat 6 can support up to 1 gigabit speeds over general distances within an office, and can support up to 10 gigabit speeds over short distances depending on the installation and equipment.
- Cat 6 cabling – may be suitable for many offices. It can support general office network requirements, such as internet connectivity, using cloud services, file sharing and video conferencing. However, if not installed properly, or interference occurs, or incorrect components are used, performance may be affected.
When choosing structured cabling in Nairobi, consider how the cabling, sockets and cabinets have been planned to suit your office layout and likely changes.
Cat 6A Cabling
- Cat 6A cabling can be used to support 10G speeds across a full 100m channel. It may therefore be a good option for high density areas, servers, and/or locations with increased data, or where extra capacity for future expansion is required.
- Cat 6A cables are generally thicker than Cat 6 cables, they may take up more space within conduit and cabinets. They may therefore require more careful installation. Although this may be more than is required for some offices, it may be useful to select Cat 6A cables in areas requiring higher bandwidths, or where a longer time until upgrade is expected.
Fibre Cabling
Fibre optic cabling uses light to transfer data. It can be useful in transferring high bandwidth data between different floors, cabinets or buildings. It can support greater distances than typical copper Ethernet cabling. It is also immune to electromagnetic interference.
However, it cannot necessarily be used instead of copper cabling. Most devices will be connected to the network via copper Ethernet. Fibre cabling requires appropriate optical equipment. In practice, it may therefore be useful to include fibre cabling as part of your network backbone, and Cat 6/6A cabling for devices at desks, access points etc.
Which cable should I choose?
It depends on the needs of your office. Cat 6 cables may be ideal for connecting regular devices, Cat 6A may be ideal for giving more bandwidth capacity over normal distances, and Fibre cabling may be ideal to allow longer distances between network sections, or if high capacity and immunity to interference is a priority.
Depending on how your business is growing, you may use a combination of all three. Considerations for which cables to use should include building layout, cabling paths, network devices, current usage and expected growth. Carrying out a site survey can help ensure you choose the most appropriate cables for your routes and requirements.
Consider future expansion in your cabling network
Consider how work spaces, meeting rooms, cabinets and wireless access points will be positioned. Consider where teams may move to, and which devices will require cabled connections. If connections between different floors or buildings are required, Fibre cabling may be appropriate. Make sure cabinets can be easily accessed, and cables can be clearly labelled so they can be easily changed in the future.
Bluechip Kenya offer technology solutions to businesses across Kenya.
They provide Infrastructure, Networking and Managed IT services. They highlight local knowledge, quick response times to on-site and remote issues, and scalable solutions. Bluechip Kenya If you are looking for network cabling in Nairobi or a structured cabling provider in Nairobi, having a discussion with them around your whole network requirements can help to ensure cabling requirements match equipment, support and growth.
If you are setting up a network in a new office, or upgrading your current network, get in touch with Bluechip Kenya to discuss your structured cabling requirements. You can get a quotation or ask any questions here. Contact Bluechip Kenya Now.
FAQ
Should we choose Cat6, Cat6A or Fibre Cabling?
Cat6 cabling is suitable for most data applications in offices such as computers, VoIP telephony and wireless access points.
Cat6A cabling is suitable where you require a 10Gbps Ethernet connection or higher via full copper cabling, or to allow for increased capacity for future use.
Fibre Optic Cabling is commonly used for long distances cabling, within the backbone of a building and between cabinets.
Identify where desks, access points, CCTV and future expansions are to be placed. Consider the length of cabling required, the type of cabling conduit, Power over Ethernet requirements, and space in cabinets. Specify what cabling standard to implement. Request evidence of certification. Even high quality Cat6 cabling can perform better than high cost cabling that has been poorly implemented.
What do we need to consider during a site survey for Structured Cabling in preparation for a move?
Identify where data sockets are required – at desks, reception, meeting rooms, wireless access points, print stations, telephony stations, CCTV cameras and server racks.
Consider cabling routes, positions for data sockets, access in ceilings, cabling trunking, cabinet position, air flow, and electricity.
Identify which cables can be re-used and which should be replaced or tested.
If multiple floors are present in Nairobi, you may need extra cabinets and backbones. This could impact both cost and duration of installation. Decide what naming convention, socket numbering, certification standard and as-built diagrams to be used. Walkthrough the site with IT and Facilities staff to make sure complex routing decisions are easy.
Why is it important to label patch panels and have certification evidence?
Labelling sockets to patch panels allows easy identification of which patch panel port connects to which socket.
Having consistent naming within sockets, cabinets and diagrams makes it easy to move desks, or replace switches. It makes it less likely that CCTV cameras and wireless access points get accidentally disconnected during maintenance.
Certification evidence ensures that cabling has met the requested standard, with correct testing equipment. Ask for permanent link/channel results and what category the cabling was tested to. Ask for cable references and details of any failed tests that were fixed. Store the certification documents and updated floorplan with IT documentation. A generic statement of “passed testing” is not sufficient.
How should cabling be planned for wireless access points, CCTV and VoIP telephony?
Plan for wireless access points, CCTV and VoIP telephony as one network, even though different contractors may be providing the kit.
On the floorplan mark where each device will go. Ensure there are sockets with the correct switch port for each device.
If devices use Power over Ethernet, check that the PoE power budget of the switch is sufficient.
Ensure guest, employee, telephony and camera traffic is separated appropriately. Ensure correct security controls are in place depending on business requirements.
Allow for some extra cabling and ports for future expansion. Before handing over, check that wireless, camera and call systems are working properly. A cable test cannot guarantee good performance from applications.